Sequence the pack-level health record first; leave the cell-level readout link unregulated for now. Watching retired bus packs sit on depot pallets waiting for a price nobody will underwrite, I keep coming back to one blocker: not the radio inside the battery, but the absence of a health number any independent buyer, insurer or grader can check. Here is how the three sequencing options compare, and where I would place each bet.

What exactly are you choosing between?

The framing as a single yes-or-no question — should regulators force open cell-level readout through the intra-pack link? — hides that this is a sequencing choice among three moves, and only one can be executed this year.

OptionWhat it locks inMain riskMy read
A. Mandate open cell-level readout nowA physical-layer interface still being redesignedNo conformance test, no agreed health metric; sealed high-voltage packs resist retrofitWrong layer, wrong year
B. Pack-level record inside the battery passportState of health with method and uncertainty band, peak temperature, cycle count, resting cell-voltage spreadAccess terms still being negotiatedDo this first
C. Wait for chip-on-cell architectures to settleNothing yetDefault value capture by manufacturersConditional yes, with a dated trigger

What does the DK-NFLNK link change, and what does it not?

The engineering case for replacing copper is strong; the case that it settles data access is not. Dukosi, an Edinburgh company, has started commercial sampling of DK-NFLNK, a contactless intra-battery communication system carrying cell voltage and temperature over a single bus antenna instead of wiring harnesses, as GreencarbonWorld reported from the Pretzl Connect 2026 event in Budapest. The company then demoed the link at Embedded World 2026 and showed a battery passport-ready proof of concept alongside it at The Battery Show Europe 2026, according to its own releases.

Joseph Notaro, the company's president, put connector failure in a conventional harness at around 10 parts per million, against automotive and industrial reliability targets measured in parts per billion — an unacceptable risk in his framing. The thermal gap is the detail I would field-test in a depot: with sparse sensing, heat from a failing cell can take 10 to 15 minutes to reach an external sensor, while per-cell sensing catches an excursion before it reaches neighbours. Dukosi also claims consistent cell-level data lets operators shrink safety buffers and raise usable energy by 6% to 12%, and describes every cell carrying a digital passport on chip — maximum temperature seen, voltage history, total charge cycles — with recyclers and integrators reading the chip to sort packs for grid use or recycling. That last description leaves out a reader, a licence and a permission model.

Two caveats keep me honest: these are vendor claims for a sampling product, not audited results, and none of it touches who may read the numbers. A wired management system can be as opaque as a wireless one; copper does not make a protocol open.

Why can the industry not agree on one health number yet?

Because no standardized measurement procedure for state of health at the vehicle level has been established. That is the finding of Bilfinger, Schreiber and Lienkamp, published in npj Clean Energy on 10 October 2025, which proposes transparent, reproducible capacity- and energy-based metrics (npj Clean Energy, 2025). This is exactly why freezing a readout format now risks certifying numbers nobody independent can reproduce, and why any mandated record must carry its measurement method and an uncertainty band, not a bare percentage.

Who wins under each option?

Same cells, different winners, and read access decides the split. Take the 6% to 12% usable-energy margin at face value: behind one vendor's tool it is captured in warranty terms, certified resale and the manufacturer's own second-life programme; readable by any licensed grader, it spreads to every integrator able to price a pack.

StakeholderClosed record (default)Open pack record (Option B)
Fleet buyerReports Scope 3 on unverifiable numbersTenders a record; residual value defensible
Independent graderMust cycle-test every pack before quotingPrices from history, tests outliers only
InsurerPrices high or declinesUnderwrites a number with method and band
ManufacturerKeeps margin at every handoverCompetes on pack quality, not gatekeeping

The stakes are concrete. IDTechEx forecasts the second-life EV battery market at US$4.2B by 2035, and retired electric school bus packs still hold nearly 70% of their capacity per the Electric School Bus Initiative. Every pack arriving without trustworthy history burns tester hours and high-voltage rigging labour before an insurer will touch it. Buyer-side threads on r/batteries and Hacker News echo the same missing standardized data — anecdote, not survey evidence, so I would not build a business case on them; the 2024 reviews by Patel et al. in Frontiers in Chemistry and Song et al. in Energies cover the pathways properly.

What does the battery passport already require, and what stays open?

The access regime exists in law; its granularity is what remains to be fought over. Regulation (EU) 2023/1542 sets 18 February 2027 as the date from which each light means of transport battery, each industrial battery above 2 kWh and each electric vehicle battery placed on the market must carry an electronic record — the battery passport — as the GreencarbonWorld report notes. European Commission guidance adds the mechanics: the passport is linked to the battery through a QR code, its public part open to anyone, with repairers, recyclers and authorities seeing more. Tiered access is therefore the design intent; what a third party may query and on whose terms is the part still being negotiated.

When would a hardware mandate become the right call?

The strongest case against my sequencing is about timing, and I concede it is uncomfortable. Interfaces that ship before a rule exists tend to become the rule: DK-NFLNK is sampling in 2026, packs built around it will run years before anyone writes a conformance test, and sealed high-voltage hardware is close to impossible to retrofit with a read port afterwards. An access rule written later would govern a generation of packs already sent for shredding, and reading at pack terminals after disassembly loses the cell-level detail that made the record worth keeping. There is a second leg: peak cell temperature, voltage history and cycle count decide residual value, insurance terms and whether a pack is safe to install under a school, so holding them behind one vendor's tool shifts value to the manufacturer at every handover.

I still land where I started, for two reasons. Dukosi itself sells DK-NFLNK as a step on its C-SynQ platform toward full chip-on-cell monitoring — a migration path, in its words — so a rule written now would certify an interface the vendor expects to supersede. And a general-purpose reader able to interrogate cells inside a live high-voltage pack is an attack surface; authentication there is a safety control, Regulation 2023/1542 already establishes the access regime, and a second regime attached to the hardware layer would duplicate the first while adding failure points.

Which sequencing fits which reader?

Procurement teams gain most from moving first, because manufacturers answer tenders faster than consultations. A bus tender requiring a machine-readable health record, queryable without a vendor licence once the vehicle leaves service, changes behaviour inside one contract cycle — the lesson the UK's 2030 EV target debate keeps teaching: the percentage gets argued, the money rarely does. Insurers should demand method and uncertainty band before pricing a second-life asset. Compliance teams should note carbon accounting alone will not create the incentive — Scope 3 placement does not price a repurposed pack, the same reporting-grain problem behind the hourly load emissions case for AI data centres. The money has to come from recovered pack value, which rewards whoever grades fastest and cheapest.

What would change my mind?

One dated trigger: if the February 2027 deadline arrives and an independent grader still cannot obtain a number it can insure without the manufacturer's permission, the sequencing argument collapses and a hardware mandate becomes the remaining lever. Write that trigger down now rather than assume the softer route holds.

What should you do first?

The order I would work in:

  1. This year, while the regulation is still in draft, add a read-access clause to bus and truck tenders: machine-readable, licence-free for read-only once the pack leaves the vehicle.
  2. Agree the minimum field set — state of health plus method and uncertainty band, peak temperature, cycle count, resting cell-voltage spread — and validate it on packs already in service, not showroom-new ones.
  3. Fund at least one reference bench, so a health number can be checked against something other than the seller's own tool.
  4. Hold off on any intra-pack link requirement until chip-on-cell architectures settle, then revisit with real retrofit cost data.

My verdict in one line: run Option B now, keep Option C only until the trigger fires, and shelve Option A until the measurement standard and the silicon stop moving. That is one tender clause this quarter — not a new hardware standard.

Frequently asked questions

What is the EU battery passport and when does it take effect?

From 18 February 2027, under Article 77 of Regulation (EU) 2023/1542, every EV battery, industrial battery above 2 kWh and light means of transport battery placed on the EU market needs an electronic record linked by QR code — public part open to anyone, richer tiers for repairers, recyclers and authorities.

Does near-field RF replacing battery wiring make health data open?

No. DK-NFLNK changes failure modes and sensor density inside the pack; who gets to read the numbers is a separate commercial and regulatory arrangement.

Is there one agreed state-of-health figure for contracts?

Not yet. No standardized vehicle-level measurement procedure exists, which is why a mandated record must state its method and uncertainty band before any percentage means anything.

Can a fleet act before the regulation is final?

Yes. A tender clause binds suppliers through procurement rather than regulation and can land inside one contract cycle.

References

  • GreencarbonWorld: Dukosi starts sampling DK-NFLNK to replace battery wiring with near-field RF
  • npj Clean Energy: Why we need a standardized state of health measurement procedure for EV battery packs (Bilfinger et al., 2025)
  • European Commission: Batteries and the digital product passport
  • Dukosi: DK-NFLNK and battery passport-ready PoC at The Battery Show Europe 2026
  • IDTechEx: Second-life Electric Vehicle Batteries 2025-2035
  • Electric School Bus Initiative: Building a market for second-life electric school bus batteries
  • Frontiers in Chemistry: second-life pathway review (Patel et al., 2024)
  • Energies: overview of second-life battery utilisation (Song et al.)
Brand logo

Tech Daily

Your Daily Source for Consumer Tech, Policy & Communications

HardwarePolicy & RegulationSoftwareCommunicationsConsumer ElectronicsGeneralAPAC EdmGrowthAbout Us

© 2026 Tech Daily.

Cookie Notice

We use cookies to improve your experience and analyze website traffic. Read our Privacy Policy to learn more.