Spec'ing the TE Connectivity (TE) HC-STAK 35: A Hands-On Hardware Guide to up to 400A and 1000 V DC EV Power Links
If you are choosing a high-voltage link for an electric, hybrid, plug-in hybrid or fuel-cell platform, the real question is not whether the part fits the schematic — it is whether it survives the pack. The TE Connectivity (TE) HC-STAK 35 answers that with up to 400A of continuous current on a 95 mm² conductor at 85 °C, a rating of up to 1000 V DC, and a shielded, touch-safe housing. Below is the working checklist MyTechDailyNews uses to spec it, install it and buy it — in that order.
What the HC-STAK 35 is — and what it is not
Start with the category, because most mis-orders come from a category error. The HC-STAK 35 is a high-voltage interconnection system: the shielded, stackable links that route power among the battery, the inverter and the e-motor. It is not a charge-coupler, not a service plug and not the contactor inside the pack enclosure.
TE built this future-ready link for the rising power needs of those platforms, and Mouser Electronics, Inc. now stocks the series. A useful piece of history for your design review: TE Connectivity brought the platform to the Battery Show and told Design News that the HC-STAK 35 is rated at 400A continuous and can be employed in DC fast-charge duty, with engineers expecting the technology to appeal inside and outside the auto industry. That framing still holds — this is a busbar-class interconnect, sized for drivetrain current, not for a charging inlet.
Which HC-STAK member should you actually specify?
Conclusion first: buy headroom in contact points and in thermal margin, not in copper. Press coverage usually stops at the top figure in the family — up to 400A — but TE documents three rungs, and the cheapest compliant design is normally the smallest one that clears your derated current.
| Variant | Continuous current (as documented) | Conductor size | Layered fork contacts | Voltage class |
| HC-STAK 25 | up to 247 A at 85 °C | 50 mm² wire | fork-terminal stack | 1000 V DC |
| HC-STAK 25 XE | up to 296 A at +85 °C | 70 mm² conductors | up to 40 independent contact points | 1000 V DC |
| HC-STAK 35 | up to 400A at 85 °C | 95 mm² wire | up to 64 layered contact points | up to 1000 V DC |
Figures are from TE's own HC-STAK series page and the HC-STAK 25 and HC-STAK 25 XE product documents. Read as a decision rule: a 200 A city-car drive unit that never sees a trailer hitch is over-coppered on the HC-STAK 35, while a dual-motor AWD platform with towing duty sits exactly where TE targets this part — platforms with higher curb weight, AWD systems, or integrated towing capabilities.
How to turn the 400A headline into a real design limit
Conclusion first: the current figure is a thermal statement, not an electrical one.
- Re-read the reference condition. The HC-STAK 35 supports up to 400A with 95 mm² wires at 85 °C. Establish your worst-case interface temperature, not the pack average, before you accept that number.
- Design to the ceiling, not to the lab. TE's series documentation gives an operating window of -40 °C to +125 °C; a routing that only works at 25 °C bench conditions is not a routing.
- Hunt the resistance. The scalable fork-terminal architecture offers up to 64 layered contact points, and optional ultrasonic welding keeps the interface low-resistance — that combination is what reduces power loss and heat generation.
- Do not solve heat by adding copper. The compact, lightweight layout exists to fit space-constrained applications; stepping up cable size to dodge a thermal analysis charges you twice, in mass and in packaging.
- Keep EMI in the power path. Shielding is integral when current moves between those power nodes — but it only works if the shield is terminated and measured, see step 5 below.
Six steps from sample kit to a production build
- Freeze the safety target. Write down the voltage class and the standard you will be assessed against; for high-voltage circuits on electrically propelled road vehicles, ISO 6469-3 (voltage class B electrical safety) is the usual anchor.
- Do the thermal math before the connector choice. Continuous current, peak duration, ambient soak, and whether a 95 mm² cable can physically be routed where you need it — that bend radius has killed more programs than the connector itself.
- Validate the termination process. Confirm the crimp die set or the ultrasonic-weld parameters with your tooling supplier, then measure interface resistance on the first articles. A wrong die shows up months later as a hot joint.
- Wire the interlock properly. A high-voltage interlock loop is a low-voltage monitoring circuit routed through the power connectors, and its signal path is designed to break before the main contacts separate. Verify the sequencing on the mating housing, not only on the drawing.
- Close the shield. Terminate shielding 360 degrees and record a shield-continuity value per assembly, so EMC testing does not become the first time anyone checks the interconnect.
- Collect evidence, not checkboxes. Pull the touch-safe, ingress and flammability test reports and bind them to the exact part numbers you bought — IP2XB, IP67 and V0 mean different failure modes and different tests.
What IP2XB, IP67 and V0 actually protect you from
Conclusion first: three hazards, three test methods. Treating them as one ruggedness badge is the most common sourcing mistake in this component class.
- IP2XB — touch-safe. Guards against a finger reaching live parts. Regulators describe the equivalent IPXXB requirement as probing the protective barrier with a jointed test finger, in the FMVSS rulemaking record on electric-powered vehicles.
- IP67 — ingress. Dust-tight and able to survive temporary immersion; relevant to underbody routing, wash bays and service exposure. It says nothing about whether the interlock loop is intact.
- V0 — flammability. A vertical-burn classification for the housing material, aimed at fire propagation. It is unrelated to mechanical strength or sealing.
On top of those three, the interconnects are built to withstand vibration, mechanical stress and thermal stress — which is what lets a shielded, touch-safe link live inside a moving pack rather than on a test bench.
Five mistakes that cost weeks on an HV program
- Specifying on the headline amperage alone and ignoring the 95 mm² / 85 °C reference condition behind it.
- Assuming the family is interchangeable: the 25-series housings and the HC-STAK 35 are not the same current and contact-count story.
- Reading IP67 as an EMC or an interlock guarantee, then failing a radiated-emissions retest that a measured shield termination would have prevented.
- Skipping interlock sequencing checks during service and retrofit work, where the loop is the last layer between a technician and a live circuit.
- Buying outside a certified channel to save a few weeks of lead time on parts that must be genuine and traceable end-to-end.
How to source it traceable — and what to check on the invoice
Conclusion first: high-voltage interconnects are a counterfeit-and-revision risk, so the channel is part of the specification, not an afterthought.
As a global authorized distributor, Mouser offers the widest selection of the newest semiconductors and electronic components with stock ready to ship, and parts supplied through that channel are 100% certified, genuine and fully traceable from manufacturer partners. The practical advantage showed up in Mouser's 2025 TE Connectivity supplier announcement: more than 750,000 TE part numbers available to order, with over 75,000 already in stock — the depth you need when one shipment has to carry HC-STAK 35 housings plus the smaller contacts and seals. Before the production order, work the technical library: the Technical Resource Center, data sheets, supplier-specific reference designs, application notes, design information and engineering tools are published on the distributor site, and they are what shorten the first-article loop.
Action recommendations
- Move to the HC-STAK 35 when derated continuous current, conductor size and interface temperature all clear your worst case; otherwise stay on the smallest family member that does — this is our analysis, not a vendor claim.
- Add a shield-continuity measurement and an interlock-sequencing check to the end-of-line test plan for every HV assembly, not only the first build.
- Ask your supplier for the test evidence behind IP2XB, IP67 and V0 tied to the delivered lot code, and file it with the BOM revision.
- Run a second-source or lifecycle check on the exact terminations and seals at design freeze, so a mid-program change does not force a fresh EMC campaign.
Frequently asked questions
Is the HC-STAK 35 only for battery-electric cars?
No. The series is intended for electric, hybrid, plug-in hybrid and fuel-cell vehicles, wherever power has to be routed among the battery, inverter and e-motor.
Why does the temperature rating matter more than the current rating?
Because the amperage figure is defined at a stated thermal condition — up to 400A with 95 mm² wires at 85 °C — and the series is documented for -40 °C to +125 °C operation. Your margin is the difference between those two numbers, not the marketing figure.
Do I have to use ultrasonic welding?
It is optional. The benefit is a lower-resistance interface alongside the fork terminals, which cuts power loss and heat; whether your process line can support it is a tooling question, so price it early.
Can it be used in fast-charge duty cycles?
TE presented the 400A-continuous platform as usable in DC fast-charge applications, which is the argument for its thermal and contact-point headroom rather than for a larger voltage rating — the ceiling in this family is up to 1000 V DC.
Where do I get the documentation before ordering samples?
On the distributor site: data sheets, reference designs, application notes and engineering tools sit in the Technical Resource Center, alongside the HC-STAK listing.
Reference sources
- TE Connectivity — HC-STAK Series high-voltage interconnection system overview: https://www.te.com/en/products/connectors/automotive-connectors/intersection/hc-stak-series-high-voltage-interconnection-system.html
- TE Connectivity — HC-STAK 25 product e-card: https://www.te.com/content/dam/te-com/documents/automotive/global/e-card-hc-stak-25.pdf
- TE Connectivity — HC-STAK 25 XE product flyer: https://www.te.com/content/dam/te-com/documents/automotive/global/hc-stak25-xe-flyer-v3-022526.pdf
- Design News — Connector System Handles the Heat of EV Charging (2018): https://www.designnews.com/electric-vehicles/connector-system-handles-the-heat-of-ev-charging
- ISO — ISO 6469-3, electrically propelled road vehicles, electrical safety for voltage class B: https://www.iso.org/standard/68667.html
- Federal Register — FMVSS rulemaking on electric-powered vehicles, touch-protection probing: https://www.federalregister.gov/documents/2017-09-27/2017-20350/federal-motor-vehicle-safety-standards-electric-powered-vehicles-electrolyte-spillage-and-electrical
- Aptiv — What is HVIL (high-voltage interlock loop): https://www.aptiv.com/en/insights/article/what-is-hvil