Verdict first: co-packaged optics (CPO) deserves a trial in AI data-centre switches only where the optical engine and its light source stay separately tested, separately counted in failure reports, and replaceable without touching the ASIC package. The efficiency claim is measurable — a 65 percent optical power saving at 800G, about 5.4 watts for the optical engine plus laser against roughly 15 watts for a 2 x FR4 pluggable at the same bandwidth. The unresolved variable is repair depth: whether one bad fibre lane costs a module swap, a line card intervention, or a whole switch replacement.
MyTechDailyNews Hardware treats the Celestica and Broadcom session at the OCP Global Summit, Meta's ECOC comparison, Broadcom's Bailly switch testing and Nvidia's Spectrum-6 shipping list as engineering evidence rather than vendor narrative. The genuine gain is electrical path length; the consequential change is that maintenance now has to live inside a denser, hotter package. Below, DSP pluggables, linear pluggable optics (LPO), near-package optics (NPO) and two classes of CPO are compared on the axes that decide a purchase: measured power, failure unit, rack requirements, spare logistics and upgrade life.
It is real, and it is narrower than the headline. Every public figure that supports CPO measures the optical path, not the switch as a delivered system.
Third-party measurement compresses the gap. A 2026 Journal of Lightwave Technology comparison of data-centre switch power calculates that CPO improves energy per bit by 23 percent against LPO and by 67 percent against DSP pluggables for 800 Gbps links (Optica / JLT). Two buyer conclusions follow. First, LPO already captures a large share of the interconnect saving without any packaging change: module vendors and an IEEE Electronic Packaging Society overview place 800G linear pluggables in roughly the 4 to 8.5 watt band, against 13 watts and up for DSP-based modules, at the cost of a much shorter and cleaner electrical channel. Second, the 65 percent figure is optical power inside the link, so the residual difference must still be paid back through thermal design, control logic, calibration labour and field service before it becomes a rack-level number.
| Claimed metric | Public value | Scope of the measurement | How to use it in a purchase case |
|---|---|---|---|
| 800G optical link power | ~15 W pluggable vs ~5.4 W CPO engine + laser | Optical path only (Meta ECOC via QQ News) | Valid for fabric power modelling; not switch-level |
| Optical power reduction, 102.4 Tbps class | More than 70 percent | Supplier claim (Broadcom, via Xueqiu) | Request the same test bench conditions in writing |
| Total switch power vs pluggable | Up to five times lower | Supplier claim (Nvidia Spectrum-6) | Ask whether cooling and laser drive power are netted |
| Energy per bit vs LPO / DSP pluggable | +23 percent / +67 percent | Independent academic comparison (JLT, 2026) | Best neutral baseline for a three-option trade study |
| Interconnect energy, pluggable baseline | More than 11 pJ per bit | OCP APAC materials | Anchors why conversion closer to the ASIC appeals |
The honest answer for first-generation products is: the laser has been moved out, the optical engine mostly has not. That distinction should drive how you score each platform.
Both the Broadcom and Nvidia designs keep the high-power lasers off the main switch package and use external, pluggable light-source modules, as APNIC's engineering deep dive on co-packaged optics notes (APNIC). Broadcom's Bailly 51.2T pair — a Tomahawk-class ASIC with eight silicon photonics engines and an externally pluggable light source — is a working example, and the OIF's ELSFP Implementation Agreement, published in August 2023, standardises a front-panel pluggable external laser that can feed one or more optical engines under CMIS management (OIF). Lambda's unboxing of an early Nvidia co-packaged optics sample counts 18 removable external light-source modules, each feeding eight MPO ports (Lambda). A standardised, serialised, front-replaceable laser is a genuine serviceability win, and it is the single strongest argument that the industry has not abandoned the field-replaceable unit.
What remains inside the package is the optical engine, the die-to-engine attach and the fibre routing. A Tencent reassessment of CPO makes the counter-case explicit: in a highly integrated AI node, a single optical interface fault or performance degradation may affect the whole package beyond a removable module; heterogeneous chip yield losses can accumulate; and a maintenance model built around hot-swappable optics loses its fit, especially where accelerator life cycles are short and interconnect topologies change quickly. The practical repair path then looks like this:
Reliability reporting has improved, but it is still supplier-side evidence. Broadcom's Bailly 51.2T CPO switch accumulated one million 400G-equivalent port hours without link flapping in Meta's test, and later disclosed tests reached tens of millions of port hours. Read as analysis rather than fact, a fleet cost model makes the gap obvious: annual optical fault exposure is roughly the product of engine failure rate, port count, blast radius per fault, and the sum of repair hours times downtime cost, parts cost and spare inventory carrying cost. Mean time between failures answers only the first term. It does not answer whether a bad interface becomes a module swap, a line card repair, or a whole switch replacement.
CPO is not a drop-in for an air-cooled rack. The shipping platforms make that visible in hardware terms:
| Decision axis | DSP pluggable (800G) | LPO pluggable | Near-package optics | CPO with separable engine | Sealed CPO |
|---|---|---|---|---|---|
| 800G link power | ~13-15 W class | ~4-8.5 W, vendor-published | Between LPO and CPO | ~5.4 W incl. laser (Meta test) | ~5.4 W incl. laser |
| Unit of replacement | Module, front of panel | Module, front of panel | Near-package optic, board access | Optical engine + external laser | Line card or whole switch |
| Fault blast radius | One or two ports | One or two ports | One engine group | One engine group | Whole ASIC package |
| Multi-vendor optics | Yes | Yes, with link training caveats | Limited | Limited; laser standardised via ELSFP | No |
| Rack requirements | Air or liquid | Air or liquid | Usually liquid assist | Liquid cooled, 48V, fibre tray | Liquid cooled, 48V, fibre tray |
| Upgrade life | Change module, keep switch | Change module, keep switch | Partial | Engine-level only | Tied to switch ASIC generation |
| Best fit | Retrofit, mixed fleets | Short-reach dense fabrics | Bridging generation | Greenfield liquid-cooled AI fabrics | Hyperscale with in-house board repair |
Not yet, which is why the correct 2026 posture is conditional integration. ASE's account of the packaging chain, via the UBS summary, lists at least four dedicated test insertion points: die test, chip-on-wafer test after integration, optical engine unit test, and final system-level CPO package test. Those four points define the minimum evidence chain. A supplier who can demonstrate link activity on a reference board has not yet answered serviceability, because that only becomes real when production inspection can isolate and test the optical engine.
The schedule agrees. Third Bridge analysis from June still lists manufacturing yield, packaging complexity and long-term reliability as open issues, and the OCP open silicon photonics blueprint is expected to submit early work in the fourth quarter of 2026. Astera Labs' route timetable, cited by Xueqiu, places 200 Gbps per lane near-package optics in 2026 to 2027, CPO switches and 400 Gbps per lane schemes between 2026 and 2029, and fully optical designs closer to after 2030. Near-package optics deserves support precisely because it tests the service question while keeping most of the path-shortening advantage.
Try CPO now if you can tick most of these:
Stay on pluggables or LPO if any of these apply: air-cooled retrofit, rapidly changing topologies, mixed-vendor optics as a purchasing principle, short accelerator refresh cycles, or a support model that cannot absorb a multi-day requalification window. The same test applies to rack serviceability across mixed accelerator fabrics as it does to optics: a platform that cannot prove a clean fault boundary at the shelf level will not prove it inside a package. Operators should avoid CPO in rapidly changing topologies when the optical engine cannot be upgraded or bypassed without replacing the main semiconductor package, and should never treat mean time between failures as a substitute for replacement logistics.
Ready for evaluation and limited, well-instrumented deployment; not ready to be the default. Shipping evidence exists — Broadcom's Bailly 51.2T at one million 400G-equivalent port hours without link flapping, Nvidia's Spectrum-6 units in service at five named operators — while yield, packaging complexity and long-term reliability remain open issues, and the OCP open silicon photonics blueprint only expects early submissions in the fourth quarter of 2026.
You give it up for the optical engine in sealed designs, but not for the laser. ELSFP, standardised by the OIF in August 2023, keeps the light source a front-panel field-replaceable unit, and both major switch designs implement it.
A substantial share. Linear pluggable optics remove the DSP and land in the 4 to 8.5 watt band at 800G according to module vendor data, and the Journal of Lightwave Technology comparison puts CPO's energy-per-bit advantage over LPO at 23 percent — far smaller than the advantage over DSP pluggables.
Engine-level failure counts, the calibration window before alignment drift triggers a service event, and which of ASE's four test insertion points run on production units rather than evaluation boards.
The Celestica and Broadcom framing at the OCP Global Summit lists power, latency and thermal overhead as the targets, with signal integrity preserved by shortening the electrical distance. In practice, DSP removal dominates link latency figures, and for storage or HPC links the difference is usually small next to software and queueing effects.
The path that deserves support is measured integration: Celestica and Broadcom's OCP discussion links silicon photonics to manufacturing and design, ASE's test insertion points supply a practical evidence chain, the reliability figures justify trials, and the roadmap supports starting with near-package optics. That judgement holds while vendors keep the optical engine separable, open standards improve interoperability, and operators receive data that makes fault domains visible. If those conditions disappear, CPO becomes an expensive repair risk — and that, not the pJ per bit, is the number to put in front of procurement.
Reviewed and written by Sarah Chen, MyTechDailyNews Hardware desk, Tech Daily. Corrections, fleet data and benchmark requests: hello@techdaily.com.